Calculation will run with almost 2-fold (Dual Core) or 4-fold (Quad-Core) the speed.
Calculation will run up to 16-fold the speed. (Requires multiple networked sufficient PCs; Special Installation knowledge required.)

Describing text, which will appear in the log of the characteristic calculation .
Set stack height values within 0 and 250 m.
Stack opening diameter (muzzle) and the exhaust volume rate determine the mechanical lift of the plume. Set values within 0.1 m and 50 m.
Set exhaust volume rate in standard state. Set exhaust volume rate between 1 and 500.
Temperature (upper opening, muzzle) and exhaust volume rate of the waste gas determine the emission of heat and therefore the thermal lift of plume. The ambient air temperature must not fall below 10°C. Set temperature between 10 and 50°C.
Settling velocity of particles in the waste gas plume. Set sedimentation velocity between 0.01 m/s and 5 m/s.
The extent of deposition of material on the ground. Set values between 0.01 m/s and 5 m/s.
The concentration array calculation stores information for waste gas plumes of this distance. In the characteristics calculation, the distances between receptor points and sources may not exceed this value. Set values between 50 m and 100.000 m.