P&K 3781

Beispiel: Geländeprofil III; Standort B

Correction of the stack height according to VDI 3781 part 2

Geländeprofil III; Standort B

Stack height according to TA Luft [m]16,577
Waste gas plume rise [m]5,9311
Corrected stack height [m]24,3942

List of the schemata
ParameterHillValleyUndulation
x-1375-325-859,38
a154,37519578,2120
d7756502250
beta157,469213,3980,03476
lambda0,126590,100220,24987
x/d-1,7742-0,5-0,1181
HE/a0,107380,085010,21195
hE/a0,145800,115430,28778
K0,943930,688350,82132
k0,944000,691940,82298
HG*17,561824,082220,1833
hG*23,843432,528927,3494
delta_H6,281678,134707,00069
HG17,561824,394220,3487


P&K 3783 Dispersion calculation for accidental releases (emission) according to VDI 3783 part 1 and part 2 in an integrated implementation of both guidelines.



  